Consultar referencia de configuración
WL10B 10.24kWh Low-Voltage Home Battery
Use this guide for the published configuration data, the installation prerequisites and the monitoring interfaces of WL10B.
Aquí no se publican manuales de instalación, certificados, informes UN38.3 ni fichas de seguridad correspondientes al modelo exacto. Antes de comprar, pida a soporte que revise la configuración de batería/inversor, los documentos disponibles y el código postal de entrega en EE. UU. Esta referencia no sustituye al manual; no instale hasta que su instalador haya revisado las instrucciones necesarias.Configuration data
Cell chemistry: LFP
Rated voltage: 51.2V
Rated capacity: 200Ah / 10.24kWh
Max charging voltage: 57.6V
Overdischarge voltage: 44.8V
Max / peak charging current: 150A / 190A
Max / peak discharging current: 200A / 220A
Cycle life: 5,000 cycles
Weight: 88kg
Dimensions (H × W × D): 1165 × 525 × 170mm
Enclosure rating: IP54
Installation: wall mounting or floor standing
Communication interfaces include CAN, RS485, Wi-Fi and Bluetooth for monitoring through the battery or inverter interface.
Before installation
- Review the inverter communication and electrical specifications before installation.
- Confirm the delivery destination and any local receiving requirements.
- Use a qualified installer and follow local electrical requirements.
- Confirm that the mounting surface, clearance and cable routing suit the selected wall or floor position; WL10B is heavier than WL5A and needs suitable fixing.
Monitoring and communication
WL10B communicates over CAN and RS485 with the inverter or system controller, and additionally lists Wi-Fi and Bluetooth for monitoring. Up to nine sets can be connected in one system; confirm the exact configuration with your installer before purchase.
Safety and handling
- Installation and wiring must be carried out by a qualified installer.
- Verify polarity and torque all connections before commissioning.
- Keep the battery away from water, heat sources, sparks and open flames.
- Do not open, modify or repair the battery enclosure.
- Do not connect loads or chargers outside the ratings listed above.
- Follow local electrical code for breakers, fuses and disconnects.
Documents and certification status
Aquí no se publican manuales de instalación, certificados, informes UN38.3 ni fichas de seguridad correspondientes al modelo exacto. Antes de comprar, pida a soporte que revise la configuración de batería/inversor, los documentos disponibles y el código postal de entrega en EE. UU. Esta referencia no sustituye al manual; no instale hasta que su instalador haya revisado las instrucciones necesarias.